APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4040 Issued:1959-05-01
Revised:2011-12-23
Style 4040 Parallel cable with extrueded integral insulation

Rating90 deg C, 300 Vac, Horizontal flame, Oil Resistant 60 deg C (optional).
ConductorTwo No. 14, 12, 10 AWG consisting of No. 30 AWG or smaller copper strands.
InsulationIntegral with Jacket. NR - NEOPRENE, 80 mils wall Class 17 neoprene or see Facing Page and the following (pin gauge) dimensions: Wall thickness: 0.078 in., Web thickness: 0.109 in., Wall after rip: 0.043 in.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Room Cooler Units where ripped not more than 3 in unless installed in a separate metal enclosure. Additional ratings: a) Where exposed to oil at a temperature not exceeding 60 deg C. b) "125 deg C in air", see Facing Page for Compound.

UL and the UL Logo are trademarks of UL LLC © 2024