APPLIANCE WIRING MATERIAL
Subj.758
Section
4
Page
4043
Issued:
1959-05-01
Revised:
2008-05-27
Style
4043
Style SP Cord.
Rating
75 deg C, 300 Vac, Horizontal flame, Oil Resistant 60 deg C.
Conductor
14 AWG - 10 AWG consisting of No. 30 AWG or smaller solid or stranded round, tinned or bare copper.
Insulation
Integral with Jacket. NR - NEOPRENE, 80 mils min average, 72 mils minimum at any point.
Assembly
Three conductor, same as type SP with a nominal 80 mils wall the following (pin gauge) dimensions: Wall thickness: 0.070 in., Web thickness: 0.109 in., Wall after rip: 0.043 in.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal Wiring of Room Cooler Units where ripped not more than three inches unless installed in a separate metal enclosure and where exposed to oil at a temperature not exceeding 60 deg C. Polarity identification may be omitted.