APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4051 Issued:1959-05-01
Revised:2012-07-23
Style 4051 Parallel cable with extruded integral insulation and jacket

Rating75 deg C, 600 Vac, Horizontal flame, Oil Resistant 60 deg C.
Conductor14 AWG - 10 AWG solid or stranded round, tinned or bare copper, No. 30 AWG or smaller copper strands.
InsulationIntegral with Jacket. NR - NEOPRENE, 80 mils min average, 72 mils minimum at any point.
AssemblyThree conductors, same as type SP cord and the following (Pin Gauge) dimensions: Wall thickness: 0.070 inches Web thickness: 0.141 inches Wall after rip: 0.058 inches
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use only in Internal Wiring of Room Coolers where exposed to temperatures not exceeding 75 deg C and where exposed to oil at a temperature not exceeding 60 deg C. Polarity identification may be omitted.