APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4052 Issued:1959-05-01
Revised:2012-05-10
Style 4052 Parallel cable with extruded integral insulation and jacket

Rating90 deg C, 600 Vac, Horizontal Flame, Optional - Oil Resistant 60 deg C.
Conductor14 AWG - 10 AWG, Solid or Stranded Round, Stranding Consisting of No. 30 AWG or smaller strands.
InsulationIntegral with Jacket. Extruded Neoprene, 80 mils minimum average, 72 mils minimum at any point.
AssemblyThree conductors, same as type SP cord with a nominal 80 mils wall and the following (Pin Gauge) dimensions: Wall thickness: 70 mils Web thickness: 141 mils Wall after rip: 58 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Room Cooler or Remote Outdoor Condensing Units for Domestic Cooling Systems. Polarity identification may be omitted.