APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4055 Issued:1959-05-01
Revised:2012-04-09
Style 4055 Parallel cable with extruded integral insulation and jacket.

Rating75 deg C, 600 Vac, Horizontal flame, Optional - 60 deg C Oil.
Conductor18 AWG - 16 AWG, stranded consisting of 30 AWG or smaller strands.
Integral Insulation and JacketExtruded Neoprene. Same as for Type SP Cord with a nominal 60 mils wall and the following (Pin Gauge) dimensions: Wall thickness - 58 mils. Web thickness - 141 mils. Wall after rip - 58 mils.
AssemblyTwo conductor, same as for Type SP Cord
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024