APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4056 Issued:1959-05-01
Revised:2012-04-09
Style 4056 Parallel cable with extruded integral insulation and jacket.

Rating90 deg C, 600 Vac, Horizontal flame, Oil Resistant 60 deg C (optional).
ConductorTwo No. 18, 16 AWG consisting of No. 30 AWG or smaller strands.
InsulationIntegral with Jacket. Extruded NR - NEOPRENE, 58 mils min average, 52 mils minimum at any point and the following (Pin Gauge) dimensions: Wall thickness: 58 mils Web thickness: 141 mils Wall after rip: 58 mils
AssemblyTwo conductors, parallel construction, same as type SP Cord.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators and where exposed to temperatures not exceeding 90 deg C. May add: and where exposed to oil at a temperature not exceeding 60 deg C. Polarity identification may be omitted.