APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4081 Issued:1959-05-01
Revised:2012-05-10
Style 4081 Multiple-conductor cable using non-extruded non-integral covering.

Rating60 deg C, 300 Vac, Horizontal Flame.
ConductorTwo special tinsel conductors, 23 AWG, an assembly of 42 strands No. 6 tinsel consisting of three groups having a rope lay, each group consisting of 14 strands, and each strand consisting of a flattened, 39 AWG copper wire wound around a 2-ply cotton thread core. A cotton separator shall be used.
InsulationExtruded SRB/NR, 15 mils minimum average thickness. Cotton braid on individual insulated conductor.
AssemblyConductors shall be twisted with a maximum lay of 1 inch (a 5% tolerance shall be permitted). A cotton filler shall be provided. Binder over assembled conductors shall be optional.
CoveringNon-Extruded Glazed Cotton Braid shall be provided over the assembled conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring for Use Only as the connection between the motor and base of oscillating fans.

UL and the UL Logo are trademarks of UL LLC © 2024