Rating | 60 deg C, 300 Vac, Horizontal Flame. |
|
Conductor | 105 strands of 40 AWG conductor. Conductors shall be provided with a cotton separator, maximum lay of bunch stranded conductors shall be 1 inch. |
|
Insulation | Extruded SBR/NR, 30 mils minimum average thickness, 27 mils minimum thickness at any point. Each individual insulated conductor is closely woven with rayon braid. |
|
Assembly | Three insulated conductors shall be twisted with a maximum length of lay of 2 inches (a 5% tolerance shall be provided). A cotton filler shall be provided. Binder over assembled conductors shall be optional. |
|
Covering | A glazed cotton braid shall be provided over the assembled insulated conductors. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For use only as the connection between the motor and base of oscillating fans. Polarity identification: Braids of contrasting colors on the individual conductors, or tracers of contrasting colors in white braid. |
|