APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4084 Issued:1959-05-01
Revised:2012-07-30
Style 4084 Multiple conductor cable with extruded insulation and non-extruded covering

Rating60 deg C, 300 Vac.
ConductorTwo - 105 40 AWG copper strands provided with a cotton separator. Maximum lay of bunch stranded conductors shall be 1 inch.
InsulationExtruded SBR/NR, extruded NR or extruded EP, 30 mils min average, 27 mils minimum at any point, closely woven rayon braid on individual insulated conductors.
AssemblyTwo conductors shall be twisted with a maximum lay of 1-3/4 inches (a 5% tolerance shall be provided). A cotton filler shall be provided. Binder over assembled conductors shall be optional.
CoveringA glazed cotton braid shall be provided over the assembled conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use only as the connection between the motor and base of oscillating fans. Polarity identification: Braids of contrasting colors on the individual conductors, or tracers of contrasting colors in white braid.

UL and the UL Logo are trademarks of UL LLC © 2024