Rating | 60 deg C, 300 Vac. |
|
Conductor | 105 40 AWG copper strands provided with a cotton separator maximum lay of bunch stranded conductors shall be 1 inch. |
|
Insulation | SRB/NR, 15 mils min average, 14 mils minimum at any point, closely woven rayon braid on individual insulated conductor. |
|
Assembly | Three conductors shall be twisted with a maximum lay of 2 inches (a 5% tolerance shall be permitted). Binders over assembled conductors shall be optional. |
|
Covering | A glazed cotton braid shall be provided over the assembled conductors. |
|
Braid | Optional. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For use only as the connection between the motor and base of oscillating fans. Polarity identification: Braids of contrasting colors on the individual conductors, or tracers of contrasting colors in white braid. |
|