Rating | 60 deg C, 300 Vac, FT2 flame. |
|
Conductor | 18 AWG - 16 AWG smaller stranded. |
|
Insulation | SRB/NR, 30 mils min average. |
|
Assembly | Four conductors, same as type SJ Cord,consisting of three No. 18 AWG conductors with black, red and brown insulation respectively and one No. 16 AWG conductor with white insulation, otherwise the same as for Type SJ Cord. |
|
Jacket | SRB/NR, 30 mils min average. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. The tag shall also contain the following information: "The No. 16 AWG conductor shall be insulated with a white colored insulation while the individual No. 18 AWG conductors shall have a black, red and 1brown colored insulation. |
|
Use | Internal Wiring of Refrigeration Equipment at temperature not exceeding 60 deg C. The tag shall also contain the following information: "The No. 16 AWG conductor shall be insulated with a white colored insulation while the individual No. 18 AWG conductors shall have a black, red and 1brown colored insulation. |
|