APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4089 Issued:1959-05-01
Revised:2012-07-24
Style 4089 Multiple-conductor cable using non-integral insulation

Rating75 deg C, 300 Vac, FT2 flame.
Conductor18 AWG - 16 AWG smaller stranded, tinned or bare copper.
InsulationSRB/NR, 30 mils min average, 27 mils minimum at any point.
AssemblyFour conductors, same as type SJ Cord, except consisting of three No. 18 AWG conductors with black, red and brown insulation respectively and one No. 16 AWG conductor with white insulation.
JacketSRB/NR, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral. The tag shall also contain the following information: "The No. 16 AWG Conductor shall be insulated with a white colored insulation while the individual No. 18 AWG. Conductors shall have a black, red, and brown colored insulation."
UseInternal Wiring of Refrigeration Equipment at temperatures not exceeding 75 deg C. The tag shall also contain the following information: "The No. 16 AWG Conductor shall be insulated with a white colored insulation while the individual No. 18 AWG. Conductors shall have a black, red, and brown colored insulation."