APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4093 Issued:1959-05-01
Revised:2012-04-24
Style 4093 Single conductor with extruded insulation.

Rating75 deg C, 300 Vac.
Conductor18 AWG consisting of 16-30 AWG strands.
InsulationExtruded SRB/NR, 15 mils minimum average thickness, 14 mils minimum thickness at any point.
AssemblyIndividual conductors twisted together. The twisted conductors shall then be wrapped in a cloth tape, the outer face of which shall be coated with rubber.
CoveringCotton or rayon braid on individual insulated conductors. A closely woven lacquered cotton or rayon braid shall be provided over the assembled conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseOnly between the switch and motor of ventilating fans where the acceptability of the combination has been determined by Underwriters Laboratories Inc. Note: This cord connects the fan motor to the switch and is fixed in position to prevent undue flexing.