APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4094 Issued:1959-05-01
Revised:2012-02-16
Style 4094 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, FT2 flame.
Conductor18 AWG - 10 AWG solid or stranded round
InsulationExtruded CP or extruded CPE or extruded EP or extruded NBR/PVC or extruded Neoprene or extruded SRB/NR or extruded XL, 30 mils minimum average thickness, 27 mils minimum thickness at any point, except insulation may be of any color.
AssemblySame as type SJ Cord.
JacketExtruded CP or extruded EPDM or extruded NBR/PVC or extruded Neoprene or extruded SRB/NR, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Refrigerator Show Window Cases. Polarity indentification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024