Rating | 60 deg C, 300 Vac. Horizontal flame. |
|
Conductor | Two, No. 20 or 18 AWG, solid or stranded, tinned or bare. |
|
Insulation | SRB/NR, 15 mils min average, 13 mils minimum at any point. |
|
Shield | One or both conductors may have shielding consisting of No. 36- or 34 AWG, tinned or bare, copper strands applied as a wrap or braid. |
|
Jacket | SRB/NR, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | As Microphone Cable in Electronic Appliances at a Maximum Operating Temperature of 60 deg C. |
|