APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4111 Issued:1959-05-01
Revised:2012-05-10
Style 4111 Multiple-conductor cable using non-integral extruded jacket

Rating60 deg C, 300 Vac, Horizontal Flame.
Conductor20 AWG - 18 AWG, Solid or Stranded Round.
InsulationExtruded CP or Extruded CPE or Extruded EP or Extruded NBR/PVC or Extruded Neoprene or Extruded SBR/NR or Extruded XL, 15 mils minimum average, 14 mils minimum at any point.
AssemblySeven conductors, same as type SV Cord.
JacketExtruded CP or Extruded EPDM or Extruded NBR/PVC or Extruded Neoprene or Extruded SBR/NR, 30 mils minimum average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024