APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4112 Issued:1959-05-01
Revised:2008-05-27
Style 4112 Multiconductor cable with extruded non-integral jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor20 AWG - 18 AWG solid or stranded round, tinned or bare copper.
InsulationCP or CPE or EP or NBR/PVC or NR - NEOPRENE or SRB/NR or XL, 15 mils min average, 14 mils minimum at any point.
AssemblyEight or nine conductors, same as type SV Cord.
JacketCP or EPDM or NBR/PVC or NR - NEOPRENE or SRB/NR, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAppliance wiring material, suitable for use in appliances.

UL and the UL Logo are trademarks of UL LLC © 2024