Style 4124 Parallel cable with extruded integral insulation and jacket

Rating60 deg C, 300 Vac, FT2 flame.
Conductor18 AWG consisting of No. 30 AWG or smaller strands
InsulationExtruded SRB/NR, 75 mils minimum average thickness, 68 mils minimum thickness at any point.
AssemblyThree conductors, same as type SP-1 Cord. Nominal 80 mils separation between conductors. The following minimum (pin gauge) dimensions shall apply: Wall thickness: 0.028 in. Web thickness: 0.070 in. Wall after rip: 0.028 in.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where installed within separate metal enclosures or between the walls of the cabinet. Polarity identification may be omitted.