APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4125 Issued:1959-05-01
Revised:2012-03-27
Style 4125 Parallel Cable with Extruded Integral Insulation and Jacket

Rating60 deg C, 300 Vac.
Conductor18 AWG consisting of No. No. 30 AWG or smaller, tinned or bare strands.
InsulationExtruded SRB/NR, integral with Jacket, 75 mils minimum average thickness, 68 mils minimum thickness at any point.
AssemblyFour conductors, parallel construction, same as Type SP-1 Cord. A nominal 80 mils separation between conductors. The following minimum (pin gauge) dimensions shall apply: Wall thickness: 0.028 inches, Web thickness: 0.070 inches, Wall after rip: 0.028 inches.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where installed within separate metal enclosures or between the walls of the cabinet. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024