APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4131 Issued:1959-05-01
Revised:2008-05-27
Style 4131 Parallele Cord

Rating75 deg C, 300 Vac, Oil Resistant 60 deg C.
Conductor18 AWG consisting of No. 30 AWG or smaller stranded, tinned or bare copper.
InsulationIntegral with Jacket. NR - NEOPRENE, 75 mils min average, 68 mils minimum at any point.
AssemblyFour conductors, same as type SP-1 Cord. A nominal 80 mils separation between conductors. The following minimum (pin gauge) dimensions shall apply: Wall thickness: 0.028 in., Web thickness: 0.070 in., Wall after rip: 0.028 in.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where installed within separate metal enclosures or between walls of the cabinet, and where exposed to temperatures not exceeding 75 deg C, and where exposed to oil at a temperature not exceeding 60 deg C. Polarity identification may be omitted.
 
UL and the UL Logo are trademarks of UL LLC © 2024