APPLIANCE WIRING MATERIAL
Subj.758
Section
4
Page
4132
Issued:
1959-05-01
Revised:
2008-05-27
Style
4132
Parallel Cord
Rating
90 deg C, 300 Vac, Oil Resistant 60 deg C.
Conductor
18 AWG consisting of No. 30 AWG or smaller tinned or bare copper strands.
Insulation
Integral with Jacket. NR - NEOPRENE, 75 mils min average, 68 mils minimum at any point.
Assembly
Two conductors, same as type SP-1 Cord. A nominal 80 mils separation between conductors. The following minimum (pin gauge) dimensions shall apply: Wall thickness: 0.028 in., Web thickness: 0.070 in., Wall after rip: 0.028 in.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring of electric refrigerators where installed within separate metal enclosures or between walls of the cabinet, and where exposed to temperatures not exceeding 90 deg C, and where exposed to oil at a temperature not exceeding 60 deg C. Polarity identification may be omitted.
UL and the UL Logo are trademarks of UL LLC © 2024