APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4133 Issued:1959-05-01
Revised:2012-07-30
Style 4133 Parallel cable with extruded integral insulation and jacket.

Rating90 deg C, 300 Vac, 60 deg C Oil.
Conductor18 AWG consisting of No. 30 AWG or smaller strands.
InsulationIntegral with Jacket. Extruded Neoprene, 30 mils minimum average thickness, 27 mils minimum at any point with a nominal 80 mils separation between conductors. The following minimum (pin gauge) dimensions shall apply: Wall thickness: 0.028 in. Web thickness: 0.070 in. Wall after rip: 0.028 in.
AssemblyThree conductors, same as for Type SP-1, with a nominal 80 mils separation between conductors. The following minimum (pin gauge) dimensions shall apply: Wall thickness: 0.028 in., Web thickness: 0.070 in., Wall after rip: 0.028 in.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where installed within separate metal enclosures or between walls of the cabinet. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024