APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4137 Issued:1959-05-01
Revised:2008-05-27
Style 4137 Parallel Cord

Rating75 deg C, 300 Vac, Oil Resistant 60 deg C.
Conductor20 AWG solid or stranded round, tinned or bare copper.
InsulationIntegral with Jacket. NR - NEOPRENE, 60 mils min average, 54 mils minimum at any point.
AssemblyTwo conductors, same as type SP-2 except for a nominal 60 mils and the following minimum and(pin gauge) dimensions: Wall thickness: 0.058 in., Web thickness: 0.078 in., Wall after rip: 0.028 in.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where installed within separate metal enclosures or between walls of the cabinet, and where exposed to temperatures not exceeding 75 deg C, and where exposed to oil at a temperature not exceeding 60 deg C. Polarity identification may be omitted.
 