APPLIANCE WIRING MATERIAL
Subj.758
Section
4
Page
4137
Issued:
1959-05-01
Revised:
2008-05-27
Style
4137
Parallel Cord
Rating
75 deg C, 300 Vac, Oil Resistant 60 deg C.
Conductor
20 AWG solid or stranded round, tinned or bare copper.
Insulation
Integral with Jacket. NR - NEOPRENE, 60 mils min average, 54 mils minimum at any point.
Assembly
Two conductors, same as type SP-2 except for a nominal 60 mils and the following minimum and(pin gauge) dimensions: Wall thickness: 0.058 in., Web thickness: 0.078 in., Wall after rip: 0.028 in.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring of electric refrigerators where installed within separate metal enclosures or between walls of the cabinet, and where exposed to temperatures not exceeding 75 deg C, and where exposed to oil at a temperature not exceeding 60 deg C. Polarity identification may be omitted.