APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4141 Issued:1959-05-01
Revised:2012-07-07
Style 4141 Multi-conductor cable with non-integral jacket

Rating60 deg C, 300 Vac, FT2 flame
Conductor18 AWG - 10 AWG solid or stranded round.
InsulationExtruded CP or extruded CPE or extruded EP or extruded NBR/PVC or extruded NR - NEOPRENE or extruded SRB/NR or extruded XL, 30 mils min average, 27 mils minimum at any point.
AssemblySix conductors, same as type SJ Cord.
JacketExtruded CP or extruded EPDM or extruded NBR/PVC or extruded NR - NEOPRENE or extruded SRB/NR, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn couches and hospital beds.

UL and the UL Logo are trademarks of UL LLC © 2024