APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4147 Issued:1959-05-01
Revised:2012-07-15
Style 4147 Multiple Conductor Cable using Non-Integral Non-Extruded Covering

Rating60 deg C, 300 Vac, Horizontal Flame
Conductor19 AWG Stranded Round, maximum lay of bunch stranded conductors shall be 1 inch.
InsulationExtruded SBR/NR, 15 mils minimum average, 13 mils minimum at any point.
AssemblyFive insulated conductors provided with a cotton separator. Conductors shall be twisted with a maximum lay of 2.5 inches (a 5% tolerance shall be permitted). Cotton fillers shall be provided.
CoveringNon-Extruded Glazed Cotton Braid shall be provided over the assembled conductors. Thickness not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring for use only as the connection between the motor and base of oscillating fans. Polarity identification: Braids of contrasting colors on the individual conductors, or tracers of contrasting colors in braid.

UL and the UL Logo are trademarks of UL LLC © 2024