APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4152 Issued:1959-05-01
Revised:2012-04-24
Style 4152 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
ConductorTinsel conductors. The maximum resistance of each conductor shall be 240 ohms per 1000 ft. at 25 deg C.
InsulationSame as for Type SV Cord.
AssemblyFour tinsel conductors, same as for Type SV Cord, except a maximum conductor lay of 2.375 inches. A cotton wrap shall be provided over the assembly.
ShieldOptional.
JacketSame as for Type SV Cord.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use only on dictating and transcribing machines.