APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4156 Issued:1959-05-01
Revised:2012-02-10
Style 4156 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating60 deg C, 300 Vac, FT2 flame.
ConductorTinsel conductors. The maximum resistance of each conductor shall be 240 ohms per 1000 ft at 25 deg C.
InsulationExtruded SRB/NR, extruded EP, extruded Neoprene, extruded CP or extruded NBR/PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblySix conductors, similar to Type SV cord, except 3.5 inches maximum lay of conductors.
ShieldOptional.
JacketExtruded Neoprene, extruded CP, extruded EP, extruded NBR/PVC or extruded Thermoset CPE, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use only on dictating and transcribing machines.

UL and the UL Logo are trademarks of UL LLC © 2024