| Rating | 90 deg C, 300 Vac, FT-2 Flame, Optional - Oil Resistant 60 deg C. |
|
| Conductor | 18 AWG and 16 AWG, consists of No. 30 AWG or smaller conductor strands. |
|
| Insulation | Extruded Neoprene, 60 mils minimum average thickness, 54 mils minimum thickness at any point. |
|
| Assembly | Four-conductors, same as type SP-3. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | For Internal Wiring of Lighting Circuits in the Refrigerator Walls. Polarity identification may be omitted. |
|