APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4175 Issued:1960-10-10
Revised:2012-12-11
Style 4175 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor20 AWG stranded, tinned or bare copper.
InsulationSRB/NR, 30 mils min average, 27 mils minimum at any point.
AssemblyFive conductors, same as type SJ Cord.
JacketSRB/NR, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAppliance wiring material, suitable for use in appliances.