APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4184 Issued:1961-11-15
Revised:2012-03-14
Style 4184 Parallel Cable with Extruded Integral Insulation and Jacket

Rating90 deg C, 300 Vac, Horizontal flame, Oil Resistant 60 deg C.
Conductor18 AWG - 16 AWG with 30 or finer strands.
InsulationExtruded NR - NEOPRENE, integral with Jacket, 28 mils minimum average thickness, 25 mils minimum thickness at any point.
AssemblyThree conductors, same as type SP-1 Cord, Cross-section of ripped conductor insulation shall be circular.
Minimum dimensions (pin gauge) as follows:
Wall thicknessbefore and after rip:28 mils
Web thickness:78 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Window Fans. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024