APPLIANCE WIRING MATERIAL
Subj.758
Section
4
Page
4189
Issued:
1963-02-08
Revised:
2008-05-27
Style
4189
Twisted cable
Rating
75 deg C, 300 Vac, Horizontal flame.
Conductor
26 AWG - 16 AWG stranded round, tinned or bare copper.
Insulation
Integral with Jacket. SRB/NR, 15 mils min average, 13 mils minimum at any point.
Assembly
Two conductors shall be twisted together.
Covering
Dry or treated braid over individual conductor insulation.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
For use on permanent wave heaters.