Rating | 60 deg C,voltage rating not specified, Cable flame. |
|
Conductor | 26 AWG minimum, stranded. |
|
Insulation | Extruded PVC, Labled or complies with manufacturer's AWM Procedure. |
|
Assembly | Four or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon: PETP tape: or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. Over one or more insulated conductors, non-ferrous material, braided or wrapped. |
|
Separator | Cotton braid, applied directly under the jacket. |
|
Jacket | Extruded Neoprene. |
| Diameter of cable under jacket (inches) | Average thickness (mils) | Minimum thickness at any point (mils) |
| 0.701-1.500 | 80 | 64 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | "Appliance-wiring material suitable for use with electronic computers and business machines." |
|