Rating | 90 deg C, 600 Vac, Oil Resistant 60 deg C (optional). |
|
Conductor | 18 AWG - 16 AWG consisting of 30 AWG or smaller strands, solid, round, tinned or bare. |
|
Insulation | Extruded NR - NEOPRENE, integral with Jacket, 60 mils minimum average thickness, 54 mils minimum thikcness at any point. |
|
Assembly | Four conductors, same as type SP Cord, with a nominal 60 mils wall thickness and the following (pin gauge) dimensions: |
| Wall thickness: | 58 mils |
| Web thickness: | 141 mils |
| Wall after rip: | 58 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For use in internal wiring of electric refrigerators where ripped not more than 15 inches. Polarity identification may be omitted.
|
|