Rating | 90 deg C, voltage rating not specified, Cable flame. |
|
Conductor | 26 AWG, min., stranded copper. |
|
Insulation | PVC, Labeled or complies with manufacturer's AWM Procedure. |
|
Assembly | Four or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon: oriented polyethylene terephthalate: or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. Over one or more insulated conductors, non-ferrous material, braided or wrapped. |
|
Separator | Cotton of fibrous braid, applied directly under the jacket |
|
Jacket | NR - NEOPRENE |
| dia of cable under jacket |
| 0.425 inches or less | 35 mils min average | 30 mils min at any point |
| 0.426-0.700 dia | 60 avg | 48 min |
| 0.701-1.500 dia | 80 avg | 64 min |
| 1.501-2.500 dia | 110 avg | 88 min |
| 2.501 dia or larger | 140 avg | 112 min |
|
Misc. | Separator Cotton or fibrous braid, applied directly under the jacket. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | "Appliance-wiring material suitable for use with electronic computers and business machines." |
|