Rating | 90 deg C, 600 Vac, Cable flame, Oil Resistant 60 deg C (optional), Moisture Resistant 60 deg C |
|
Conductor | 22 AWG - 1000kcmil solid or stranded round, tinned or bare copper. |
|
Insulation | Labeled AWM or singles complying with this manufacturer's AWM Procedure, having a minimum rating of 90 deg C dry, 60 deg C wet, and 600 volts. The designations of all individual conductors used in making up the cable shall be available. |
|
Assembly | Two or more. Two conductor cable may be flat or twisted. Three or more conductors shall be twisted. If more than one group is used, groups shall be twisted together. (The length of lay of the twisted conductors or groups is not specified). Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded NR - NEOPRENE |
| dia of cable under jacket |
| 0.425 inches or less | 45 mils min average | 36 mils min at any point |
| 0.426-0.700 dia | 60 avg | 48 min |
| 0.701- 1.500 dia | 110 avg | 88 min |
| 2.501 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of appliances or electronic equipment, Oil Resistant 60 deg C (optional), Moisture Resistant 60 deg C. |
|