Rating | 90 deg C, 600 Vac, Cable flame, 60 deg C Oil, 60 deg C Wet. |
|
Conductor | 22 AWG - 1000kcmil solid or stranded. |
|
Insulation | Labeled AWM or singles complying with this manufacturer's AWM Procedure. |
|
Assembly | Three or more conductors shall be twisted. If more than one group is used, groups shall be twisted together. (The length of lay of the twisted conductors or groups is not specified). Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded NBR/PVC |
| dia of cable under jacket |
| 0.425 inches or less | 45 mils min average | 36 mils min at any point |
| 0.426-0.700 dia | 60 avg | 48 min |
| 0.701- 1.500 dia | 110 avg | 88 min |
| 2.501 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|