Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 18 AWG stranded. |
|
Insulation | Extruded CP or Extruded CPE or Extruded EP or Extruded NBR/PVC or Extruded NEOPRENE or Extruded SRB/NR or Extruded XL, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
Assembly | Same as for Type SVO, SJO, OR SO. Note; 0.045 in min when coiled in form of a helix. |
|
Shield | 0.001 in polyester tape over assembly with 23 AWG stranded tinned copper drain (grounding) wire, with polyester-aluminum foil tape over polyester tape and drain wire. |
|
Jacket | Extruded CP or Extruded EPDM or Extruded NBR/PVC or Extruded NEOPRENE or Extruded SRB/NR, 30 mils min average thickness, 24 mils minimum thickness at any point. 0.045 in min when coiled in form of a helix. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|