APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4223 Issued:1971-01-15
Revised:2011-11-30
Style 4223 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 300 Vac.
Conductor24 AWG - 18 AWG solid or stranded. Different conductor sizes may be used in one cord; solid or stranded tinned or bare copper, or tinned soft cadmium copper strands, each strand No. 36 AWG.
InsulationExtruded CP or Extruded CPE or Extruded EP or Extruded NBR/PVC or Extuded Neoprene or Extruded SRB/NR or Extruded XL, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo to Fourteen conductors, same as type SVO.
JacketExtruded Neoprene, 47 mils minimum average thickness, 43 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.