APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4228 Issued:1972-02-04
Revised:2012-05-14
Style 4228 Multiple-conductor cable using non-integral extruded jacket

Rating60 deg C, Voltage Not Specified, FT2 Flame, Oil resistant insulation, 60 deg C.
Conductor18 AWG, Consisting of sixty-five 36 AWG copper strands.
InsulationExtruded SBR/NR, 31 mils minimum average, 28 mils minimum at any point.
AssemblySix Conductors are twisted together with jute of filler. The lay of conductors is 1 1/4 in. The assembly is covered with a cotton serve.
JacketExtruded CP, 47 mils minimum average, 38 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of x-ray machines.

UL and the UL Logo are trademarks of UL LLC © 2024