Rating | 60 deg C, Voltage Not Specified, FT2 Flame, Oil resistant insulation, 60 deg C. |
|
Conductor | 18 AWG, Consisting of sixty-five 36 AWG copper strands. |
|
Insulation | Extruded SBR/NR, 31 mils minimum average, 28 mils minimum at any point. |
|
Assembly | Six Conductors are twisted together with jute of filler. The lay of conductors is 1 1/4 in. The assembly is covered with a cotton serve. |
|
Jacket | Extruded CP, 47 mils minimum average, 38 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of x-ray machines. |
|