APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4229 Issued:1972-06-07
Revised:2012-07-25
Style 4229 Mutliple-conductor cable using a non-integral jacket

Rating60 deg C, voltage rating not specified, Horizontal flame.
Conductor24 AWG stranded, tinned or copper.
InsulationSR - SILICONE, 30 mils min average, 27 mils minimum at any point.
AssemblyTwo conductors laid parallel.
ShieldTinned copper braid over both conductors.
BraidOptional.
JacketSR - SILICONE, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.