APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4241 Issued:1972-08-07
Revised:2012-03-26
Style 4241 Multiple-conductor cable using non-integral jacket

Rating90 deg C Insulation, 200 deg C jacket, 600 Vac. Horizontal Flame.
Conductor18 AWG - 12 AWG, stranded nickel or copper. All copper shall be tin, nickel, or silver coated. If tinned copper strands are used they shall be 26 AWG or larger.
InsulationExtruded Silicone Rubber. 31 mils minimum average thickness, 28 mils minimum thickness at any point.
Assembly3 insulated conductors twisted together with 3 inch maximum length of lay.
JacketExtruded Neoprene. 31 mils minimum average thickness, 28 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of lighting fixture.