APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4242 Issued:1972-10-04
Revised:2019-11-07
Style 4242 Jacketed Cable

Rating90 deg C, 300 Vac, Cable flame.
Conductor22 AWG - 14 AWG, solid or stranded round, tinned or bare copper.
InsulationPVC, 22 mils min average, 18 mils minimum at any point.
AssemblyTwo or more individually insulated conductors with or without covering, or groups of insulated conductors, with or without covering, cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable butare not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon: oriented polyethylene terephthalate: or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups ofconductors.
ShieldOptional.
CoveringExtruded Nylon, 4 mils minimum thickness (Optional).
JacketNR - NEOPRENE
dia of cable under jacket
0.425 inches or less45 mils min average36 mils min at any point
0.426-0.700 dia60 avg48 min
0.701-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia or larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use in industrial fork-lift trucks.

UL and the UL Logo are trademarks of UL LLC © 2024