Rating | 90 deg C, 300 Vac, Cable flame. |
|
Conductor | 22 AWG - 14 AWG, solid or stranded round, tinned or bare copper. |
|
Insulation | PVC, 22 mils min average, 18 mils minimum at any point. |
|
Assembly | Two or more individually insulated conductors with or without covering, or groups of insulated conductors, with or without covering, cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable butare not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon: oriented polyethylene terephthalate: or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups ofconductors. |
|
Shield | Optional. |
|
Covering | Extruded Nylon, 4 mils minimum thickness (Optional). |
|
Jacket | NR - NEOPRENE |
| dia of cable under jacket |
| 0.425 inches or less | 45 mils min average | 36 mils min at any point |
| 0.426-0.700 dia | 60 avg | 48 min |
| 0.701-1.500 dia | 80 avg | 64 min |
| 1.501-2.500 dia | 110 avg | 88 min |
| 2.501 dia or larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For use in industrial fork-lift trucks. |
|