APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4251 Issued:1973-09-14
Revised:2012-04-24
Style 4251 Multiple conductor cable using non-integral jacket.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor20 AWG - 16 AWG solid or stranded.
InsulationExtruded CP or Extruded CPE or Extruded EP or Extruded NBR/PVC or Extruded NEOPRENE or Extruded SRB/NR or XL, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyTwo to six conductors, same as type SJO Cord.
JacketExtruded CP or Extruded EPDM or Extruded NBR/PVC or Extruded NEOPRENE or Extruded SRB/NR, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronics equipment.

UL and the UL Logo are trademarks of UL LLC © 2024