Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
Conductor | Tinned, tinsel conductors, each composed of six strands, each strand having two cadmium copper ribbons (rolled from No. 40 AWG wire). The two tinned cadmium copper ribbons shall be wound around a rayon or polyester yarn and all six strands cabled around a center core of rayon or polyester yarn. A cotton or polyester knit separator is provided between the conductor and insulation. |
|
Insulation | Extruded SRB/NR, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
Assembly | Four conductors, same as Type SV Cord, but with a lay of twist opposite in direction to the direction in which the helical cord is wound. Retractile Cord. |
|
Jacket | Extruded NR - NEOPRENE, 30 mils minimum average thickness, 24 mils minimum thickness at any point. The cord is vulcanized, while coiled in a helical shape on a mandrel. When the helix is stretched out and released, the cord returns to its helical form because of the elasticity of the jacket. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Suitable for hand set cord of telephones for use in Hazardous Locations. |
|