|
Rating | 90 deg C, 300 Vac, Cable flame. |
|
Conductor | 30 AWG minimum, solid or stranded round, tinned or bare copper. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure, 8 mils min average. |
|
Assembly | Individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded NR - NEOPRENE |
| dia of cable under jacket |
| 0.425 inches or less | 45 mils min average | 40 mils min at any point |
| 0.426-0.700 dia | 60 avg | 48 min |
| 0.701-1.500 dia | 78 avg | 72 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnect of electronic equipment. |
|