APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4264 Issued:1977-02-07
Revised:2011-12-02
Style 4264 Multiple-conductor jacketed cable using non-integral jacket.

Rating80, 105 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum material not specified.
InsulationExtruded XLPE or XLFRPE, solid or cellular, 4 mils minimum thickess.
AssemblyTwo to ten insulated singles may be laid parallel in one plane. May include mixed AWG sizes and may include a maximum web width of 100 mils.
ShieldOptional.
CoveringOptional. Inner - Over any or all singles, Extruded PVC, Extruded PE or Extruded FRPE. May be irradiated, 2 mils minimum at any point.
BraidOptional.
JacketExtruded PVC, 5 mils minimum average thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits.