APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4265 Issued:1977-02-10
Revised:2011-11-18
Style 4265 Multiconductor cable with extruded non-integral jacket.

Rating105 deg C, 125 Vac, Cable flame.
Conductor36 AWG - 20 AWG, solid or stranded.
InsulationExtruded FEP or extruded PFA, 7 mils minimum average thickness, 6 mils minimum thickness at any point.
AssemblyTwo or more insulated singles optionally twisted around a fluoropolymer filler or breather tube. Fillers may be used to form round cable.
JacketInner jacket - Optional. Extruded SR, 20 mils minimum average thickness, 24 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded SR.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.200 inch or less30 mils24 mils
0.201-0.300 inch45 mils36 mils
0.301-0.40060 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024