APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4276 Issued:1977-09-14
Revised:2012-07-15
Style 4276 Multiple Conductor Cable using Non-Integral Extruded Jacket

Rating90 deg C, No Voltage Specified, Cable Flame.
Conductor30 AWG - 9 AWG, Solid or Stranded Round.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketExtruded CP
diameter of cable under jacket in inchesmils minimum averagemils minimum at any point
0.425 or less4536
0.426-0.7006048
0.701-1.5007862
1.501-2.50010988
2.501 and larger140112
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024