|
Rating | 90 deg C, No Voltage Specified, Cable Flame. |
|
Conductor | 30 AWG - 9 AWG, Solid or Stranded Round. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded CP |
| diameter of cable under jacket in inches | mils minimum average | mils minimum at any point |
| 0.425 or less | 45 | 36 |
| 0.426-0.700 | 60 | 48 |
| 0.701-1.500 | 78 | 62 |
| 1.501-2.500 | 109 | 88 |
| 2.501 and larger | 140 | 112 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring or External Interconnection of Electronic Equipment. |
|