| Rating | 200 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 18 AWG - 16 AWG solid or stranded. |
|
| Insulation | Extruded SR, 15 mils minimum average thickness, 13 mils minimum thickness at any point. Labeled or complying with manufacturer's AWM procedure. Type SF-1 or Style 3122. |
|
| Assembly | Two insulated singles and optional insulated or uninsulated ground lead laid parallel. Optional Twisted Kevlar, Aramid or polyester strength member laid parallel. |
|
| Jacket | Extruded SR, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
| Braid | Optional - Polyester. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Supply leads for fixtures where not subject to mechanical abuse, and where the acceptability of the combination is determined by Underwriters Laboratories Inc. |
|