APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4291 Issued:1978-10-03
Revised:2012-05-03
Style 4291 Multiple-conductor cable using non-integral jacket.

Rating200 deg C, 300 Vac, Horizontal flame.
Conductor18 AWG - 16 AWG solid or stranded.
InsulationExtruded SR, 15 mils minimum average thickness, 13 mils minimum thickness at any point. Labeled or complying with manufacturer's AWM procedure. Type SF-1 or Style 3122.
AssemblyTwo insulated singles and optional insulated or uninsulated ground lead laid parallel. Optional Twisted Kevlar, Aramid or polyester strength member laid parallel.
JacketExtruded SR, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
BraidOptional - Polyester.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSupply leads for fixtures where not subject to mechanical abuse, and where the acceptability of the combination is determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024