APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4296 Issued:1979-04-20
Revised:2019-11-07
Style 4296 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 125 Vac, Horizontal flame.
Conductor50 AWG min, solid or stranded round
InsulationLabeled or complying with manufacturer's AWM procedure, 6 mils min average.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. The length of lay not specified.
ShieldOptional.
JacketExtruded SR - SILICONE
dia of cable under jacket
0.700 inches or less*30 mils min average24 mils min at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
*Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInterconnecting Cable for Medical Instruments.

UL and the UL Logo are trademarks of UL LLC © 2024